GREASE GOBBLER Super Enzymes FAST ACTING
GREASE GOBBLER is a powder blend of dry multi-cultured bacteria strains fortified with lipase enzymes that spring to life when mixed with water. It triggers instant action on a variety of substances that typically stop up drains, including animal fats, grease and vegetable oils. Ideal for restaurants, commercial kitchens, schools, hospitals or anywhere grease traps must be kept clean and sanitary.
GREASE GOBBLER Super Enzymes NON-TOXIC
GREASE GOBBLER is a non-toxic product that uses the natural digesting power of selected 100% gram positive bacteria strains. Grease accumulations are removed quickly, safely and naturally without the use of harsh caustics or dangerous chemicals
GREASE GOBBLER Super Enzymes
ENVIRONMENTALLY SAFE
GREASE GOBBLER digests the unpleasant build-up of animal fats, grease and vegetable oils naturally - - NO grease is flushed out into sewer lines. Regular weekly use of GREASE GOBBLER keeps water flowing smoothly through the trap to prevent back-ups and accumulations.
GREASE GOBBLER Super Enzyme ALL NATURAL
GREASE GOBBLER is a blend of multi-cultured bacteria strains, enzymes and microbial nutrients. All bacteria cultures are comprised entirely of beneficial spore-forming bacillus varieties, and are certified to be Salmonella-free. GREASE GOBBLER meets all requirements established in Federal Specification P-C-440C and Commercial Item Description A-A-11 of the U.S. Government Services Administration.
GREASE GOBBLER Super Enzyme ECONOMICAL
GREASE GOBBLER is shipped in convenient, economical power form. When dissolved in warm water and poured into grease trap, live bacteria and super-charged enzymes begin digesting grease clogs. Regular weekly maintenance with GREASE GOBBLER can reduce or eliminate the need for unpleasant manual cleaning of traps or costly plumber's visits.
GREASE GOBBLER INSTRUCTIONS
GREASE GOBBLER Super Enzymes
For use in GREASE TRAPS
Note: Grease traps should be cleaned before a maintenance program is started on other drains to prevent overloading the system.
For best results, pour GREASE GOBBLER into drain at closing time to allow bacteria and enzymes to work undisturbed overnight
INITIAL TREATMENT: 1-pound GREASE GOBBLER per every 20 cubic feet (150 gallons) of grease trap. Dissolve in one to two gallons of lukewarm (NOT HOT) water and let stand one hour to activate bacteria and enzymes. Pour mixture into grease trap or nearest drain. If grease trap is full of very hot water, flush with cold water first. Cleaning action will be faster if the floating crust in the trap is broken up before adding the digestant
WEEKLY MAINTENANCE: 1/2. pound GREASE GOBBLER per every 20 cubic feet (150 gallons) of grease trap. Dissolve in warm water and add directly to the trap to prevent back-ups and accumulations.
GREASE GOBBLER Super Enzymes
For Use as a SEWER DIGESTANT
D1RECTIONS: The dry bacteria cultures and enzymes in this formula must be activated in warm water (85 to 100 degrees F.) DO NOT USE HOT WATER! Pour slurry into waste stream at a point where adequate mixing will be achieved.
SEWAGE TREATMENT PLANTS: Use in all treatment processes where digestion (biological oxidation) takes place. The usual first point of addition is immediately after the primary clarifier. Add to liquid waste between the primary clarifier and the secondary treatment system.
TRICKLING FILTERS: Use an initial treatment of 40 pounds (or 8 to 12 pounds per million gallons of daily flow) through wet well or siphon tank. Repeat in 48 hours. For maintenance, use 3 to 6 pounds weekly per million gallons of daily flow.
OXIDATION TANKS: In aerated tanks, use 3 to 6 pounds for each million gallons of liquid sewage. Because of the efficiency of these bacteria, residence time in oxidation may be reduced accordingly. Sludge must be treated separately from liquid waste after the primary clarifier.
AEROBIC DIGISTERS: Use 2 pounds per week per 1000 cubic feet of sludge. When a heavy scum blanket or grease layer is present, double the treatment amount.
ANAEROBIC DIGESTERS: Use the same application rate as aerobic digesters. Works in harmony with anaerobic methane-producing bacteria to provide more complete digestion and steady gas production.
SETTLING TANKS: Use 1 to 2 pounds per week per each 1000 cubic feet of capacity.
IMHOFF TANKS: Use 2 pounds per week for each 1000 cubic feet of tank capacity. Distribute over surface of solids beneath gas vents, then agitate by paddle or hose.
LAGOONS. OXJDAT1ON PONDS & POLISHING PONDS: To reduce odors and sludge build-Up and improve clarification, use 1 to 2 pounds weekly per 60,000 gallons capacity. Disperse the digestant over the water or add through a wet well.
WET WELLS, LIFT STATIONS, SEWER MAINS & LATERALS: Add 11/2 pounds per 500 cubic feet directly into wet well. Digestant must get into liquid in order to activate. Treat laterals during periods of low flow. For each 500 feet of length, use 1 pound of digestant per 8 inches of pipe diameter.
GREASE GOBBLER Super Enzymes
For use as a POULTRY NESTING ADDITIVE
INITIAL TREATMENT: To control odor and formation of toxic fumes, use 3 to 4 pounds per 100 square feet. Till ground to combine, then water down with warm (NOT HOT) water.
MAINTENANCE: Increase by one half pound every week or at every change out of chickens until desired effect is achieved. It is not possible to overuse this product in this application.
|